Clinical Gastroenterology Vol.25 No.2(1-2)

Theme Perforation and it's Management in Endoscopy
Title Solutions to Prevent Perforations during Colonoscopy -- Especially in SD Junction
Publish Date 2010/02
Author Takeshi Suzuki Department of Endoscopy, The Jikei University School of Medicine
Author Tomohiro Kato Department of Endoscopy, The Jikei University School of Medicine
Author Hisao Tajiri Department of Endoscopy, The Jikei University School of Medicine / Division of Gastroenterology and Hepatology, Department of Internal Medicine, The Jikei University School of Medicine
[ Summary ] According to a nation-wide survey by the Japan Gastroenterological Endoscopy Society (JGES), the incidence of colonoscopic complications was 0.07% between 1998-2002. The majority were due to perforations. The major location of perforations is the sigmoid colon. In these cases some patients died. The etiology of perforations during colonoscopies was due to mechanical devices, Most of these cases were managed with surgical rescue. Careful performance of colonoscopy is required to prevent perforations.